Instructions:
TITAN is a light-cured composite with flow
characteristics that make it ideal for use as a liner in Class I and II
restorations, pit and fissure sealants, repair of marginal defects,
small core build-ups, porcelain repair, porcelain veneer cementation and
bonding splints. Other uses for TITAN are Class V restorations as well
as Class III and small Class IV’s.
TITAN is flowable; however it has been designed to
not slump, which provides better control in hard-to-access areas. Using
the tips provided, TITAN is easily injected directly into the cavity
preparation. The material can be shaped with the provided dispensing
tips.
PRINCIPAL USES OF TITAN
-
Cavity Liner
-
Class III
-
Class V
-
Pit and Fissure sealant
|
-
Porcelain repair
-
Margin repair
-
Core build-ups
-
Buccal repair
|
CAVITY LINER:
-
Isolate and prepare the
tooth surface to be restored.
-
Apply an adhesive, such
as the Simplicity® Self-Etch Adhesive System or Surpass Self-Etch
Adhesive System, according to the manufacturer's instructions.
-
Using the appropriate
shade of TITAN, place a 1 mm layer of TITAN onto the floor and walls
of the cavity preparation. Light-cure the layer for 20 seconds.
-
Continue to build the
restoration using the composite material of your choice. The composite
material should be used according to the manufacturer’s instructions.
COMPOSITE FILLINGS:
-
Isolate and prepare the
tooth surface to be restored.
-
Apply an adhesive, such
as the Simplicity® Self-Etch Adhesive System or Surpass Self-Etch
Adhesive System, according to the manufacturer's instructions.
-
Using the appropriate
shade of TITAN, place a 1mm to 2 mm increment of TITAN into the cavity
preparation. Light-cure for 20 seconds.
-
Continue to build the
restoration incrementally until the cavity preparation is filled to
the desired level. Light-cure each increment for 20 seconds
-
Shape and finish to
desired level.
NOTES:
-
To prevent excess
material from extruding out of the syringe, pull the plunger back
immediately after the desired amount is dispensed.
-
TITAN can be light
activated with LED, halogen or other conventional curing lights.
-
TITAN should be used
with 18 or 20 gauge tips
-
TITAN White Opaque
should be light activated for 40 seconds
|